ISI 04-1e Determination of Dry Matter in Starch Syrup in Vacuum Oven at 70 C
ISI 04-1e Determination of Dry Matter in Starch Syrup in Vacuum Oven at 70 oC
| Section / Step | Method | Notes |
|---|---|---|
| 1. Scope | ||
| The method is applicable to starch hydrolysates, syrups and dextrose mother liquor. | LT 15. Dec. 1964 Rev. LT 21. Nov. 1997 |
|
| 2. Principle | ||
| The starch sample is dried in vacuum at 70 o | ||
| 3. Reagent | ||
| 3.1 Kieselguhr | Kieselguhr, acid washed and dried. | |
| Preparation | Wash kieselguhr on a Büchner funnel with water acidified with 1 ml concentrated hydrochloric acid per l until washings turns acid (litmus). Rinse with water until chloride can no longer be detected with silver nitrate, AgNO3. Dry over night at 105 oC. Store in tight container. | |
| 4. Apparatus | ||
| 4.1 | Analytical balance weighing to the nearest 1 mg. | |
| 4.2 | Dish of aluminium or glass with tight-fitting lid | |
| 4.3 | Electrically heated vacuum oven. | |
| 4.4 | Desiccator with dry drying agent | |
| 4.5 | Small stirring rod of glass | |
| 4.6 | Glass beaker 100 ml | |
| 4.7 | Weighing pipette, Quickfit | |
| 5. Procedure | ||
| Fill 30 g kieselguhr (3.1) into dish (4.2). | ||
| Dry dish, kieselguhr and a stirring rod (4.5) 5 hours in oven (4.3) at 70 oC and max 34 mbar. | Alternatively dry at 105 oC over night. | |
| Cool dish in desiccator (4.4) to room temperature and weigh on balance (4.1). Weight = w0 | Let cool 1 hour | |
| Weigh 10 g of sample in beaker (4.6) to the nearest 1 mg. Weight = w1. | Use weighing pipette (4.7) if possible. Take equivalent to 4 g dry matter | |
| Mix with equal amount of hot water. Stir (4.5) and transfer to dish with kieselguhr. Flush beaker with 3x5 ml hot water. Stir kieselguhr and sample. | A weighing pipette make dilution and flushing superfluous | |
| Dry dish and stirring rod 5 hours in vacuum at 70 oC | With one dying step only time may be extended | |
| Cool and crush kieselguhr with stirring rod. | ||
| Dry again 10 hours in vacuum at 70 oC. | For certain purpose this step may be omitted. | |
| Close lid and cool in desiccator for 1 hour. Weigh immediately after removal from desiccator. Weight=w2 | Possibly re-heat to constant weight | |
| 6. Calculation | ||
| Dry matter (DM) in percent of sample (average results of two samples to one decimal) = | ||
| Formula | DM % = 100 x (w2 - w0) / (w1- w0) | |
| 7. Notes | ||
| Consider the refractive index method | ||
| 8. Reference | ||
| International Standard: ISO 1741 | ||
Comments