ISI 34-1e Determination of Baumé of Starch Slurry by Aerometer
1. Scope |
The method is applicable to starch slurry
|
LT 15 Jan 1998 |
2. Principle |
Slurry density is interpreted as concentration of slurry
|
|
3. Apparatus | 3.1 Aerometer 0 - 10 Béo | |
3.2 Aerometer 0 - 25 Béo | ||
3.3 Cylinder, slim 100 ml
|
||
4. Procedure | Keep aerometers floating in cylinder or bucket with water. | |
Fill cylinder (3.3) to the brim with starch slurry. Immerse appropriate aerometer (3.1 or 3.2) and let float. | ||
Read immediately the degree of Baumé on aerometer stem
|
||
5. Calculation |
Report reading as starch concentration in degree Baumé
(Béo) with one decimal
|
|
6. Note | Entrapped air has to be released and starch re-slurred before aerometer is read. | |
The centrifuge is superior to the aerometer as a process tool being indifferent to entrapped air and rapid settling starch. | ISI 33 | |
With Beaumé as entry table values of density etc may be found | ISI Starch Slurry Viscosity Table |
Comments